Diagnostic Performance of the Sysmex XN-31™ Automated Analyzer for Detecting Asymptomatic Malaria Among Blood Donors: A Comparative Cross-Sectional Study at the Regional Blood Transfusion Center of Abidjan, Côte d’Ivoire
1 Medical Mycology Laboratory, National Institute of Public Health, P.O. Box V 47, Abidjan, Côte d’Ivoire; (E.Y.); (A.J.S.M.); (W.Y.)
2 Parasitology and Mycology Department, Pharmaceutical and Biological Sciences Training Research Unit, University of Félix Houphouet-Boigny, P.O. Box V 34, Abidjan, Côte d’Ivoire; (K.E.A.); (L.H.E.K.); (V.A.B.-T.); (G.M.E.K.); (A.H.V.-B.); (F.K.K.); (A.K.-T.); (V.D.); (E.I.H.M.)
* Author to whom correspondence should be addressed.
Received: 16 Aug 2025 / Accepted: 31 Mar 2026 / Published: 22 Jun 2026
Abstract
Introduction: In malaria-endemic regions, asymptomatic Plasmodium carriage among blood donors poses a persistent threat to transfusion safety. The Sysmex XN-31™, an automated hematology analyzer that uses fluorescence flow cytometry, is a promising tool for rapidly detecting and analyzing malaria-infected red blood cells. Methods: We conducted a comparative cross-sectional study at the Regional Blood Transfusion Center of Abidjan during a low-transmission season. Blood samples from asymptomatic adult donors were screened using both Sysmex XN-31™ and microscopy on Giemsa-stained blood smears. The diagnostic performance was assessed using microscopy as the reference method, and inter-method agreement was determined using Cohen’s kappa. Molecular confirmation was not performed. Results: Among 520 donors (78% male; mean age 34.7 ± 11 years), Sysmex XN-31™ detected 10 Plasmodium-positive cases (prevalence 1.92%; 95% CI: 1.04–3.50) compared to 4 cases detected by microscopy (0.77%; 95% CI: 0.30–1.96). Half of the Sysmex XN-31™-positive samples had low parasitemia (20–100 parasites/µL), sensitivity was 100% (95% CI: 39.8–100), specificity was 98.8% (95% CI: 97.4–99.5), and Cohen’s kappa was 0.57. Five samples (1.0%) yielded indeterminate Sysmex XN-31™ results. Conclusion: Sysmex XN-31™ proved to be highly sensitive and specific in identifying asymptomatic malaria, particularly for the detection of low parasitemia levels. An integrative algorithm combining primary Sysmex XN-31™ screening with molecular confirmation for positive or indeterminate results is recommended. Multicenter evaluations that incorporate molecular confirmation and cost-effective analysis are warranted to further validate these findings.
Keywords: asymptomatic malaria; blood donors; Sysmex XN-31™; diagnostic performance; screening algorithm
OPEN ACCESS
This is an open access article distributed under the Creative Commons Attribution
License which permits unrestricted use, distribution, and reproduction in any medium,
provided the original work is properly cited. (CC BY 4.0).
CITE
Kiki Barro, P.C.; Yaudé, E.; Angora, K.E.; Kouadio, L.H.E.; Miézan, A.J.S.; Bédia-Tanoh, V.A.; Koné, G.M.E.; Vanga-Bosson, A.H.; Kassi, F.K.; Konaté-Touré, A.; Djohan, V.; Menan, E.I.H.; Yavo, W. Diagnostic Performance of the Sysmex XN-31™ Automated Analyzer for Detecting Asymptomatic Malaria Among Blood Donors: A Comparative Cross-Sectional Study at the Regional Blood Transfusion Center of Abidjan, Côte d’Ivoire. AJPME 2026, 3, 14.
Kiki Barro PC, Yaudé E, Angora KE, Kouadio LHE, Miézan AJS, Bédia-Tanoh VA, Koné GME, Vanga-Bosson AH, Kassi FK, Konaté-Touré A, Djohan V, Menan EIH, Yavo W. Diagnostic Performance of the Sysmex XN-31™ Automated Analyzer for Detecting Asymptomatic Malaria Among Blood Donors: A Comparative Cross-Sectional Study at the Regional Blood Transfusion Center of Abidjan, Côte d’Ivoire. AJPME. 2026; 3(2):14.
Kiki Barro, Pulchérie Christiane; Yaudé, Eugénie; Angora, Kpongbo Etienne; Kouadio, Lemaitre Hardy Emmanuella; Miézan, Assohoun Jean Sébastien; Bédia-Tanoh, Valérie Akoua; Koné, Gnanyo Massafoma Estelle; Vanga-Bosson, Abo Henriette; Kassi, Fulgence Kondo; Konaté-Touré, Abibatou; Djohan, Vincent; Menan, Eby Ignace Hervé; Yavo, William. 2026. "Diagnostic Performance of the Sysmex XN-31™ Automated Analyzer for Detecting Asymptomatic Malaria Among Blood Donors: A Comparative Cross-Sectional Study at the Regional Blood Transfusion Center of Abidjan, Côte d’Ivoire." AJPME 3, no. 2: 14.
Not implemented
SHARE